Refrigerated Compressed Air Dryer

Refrigerated Compressed Air Dryer
Details:
The GREAT Refrigerated Compressed Air Dryer there are different models to choose from: the rated air flow rate from 1.5Nm³/min to 65Nm³/min, the working pressure from 0.6Mpa to 1.0Mpa. We can also customize according to your needs. This device is used to remove moisture from compressed air.
Send Inquiry
Description
Send Inquiry

 

Products Description

 
3060b07a-5f9d-46ef-a250-05c167e98a35

The refrigeration dryer is the most crucial water removal equipment in the post-treatment system of the air compressor. It cools the compressed air to a certain dew point temperature (usually 2 to 10 degrees Celsius), causing the gaseous water vapor in the air to condense into liquid water droplets. Then, through the air-water separator and the automatic drainage valve, these droplets are discharged, thereby obtaining dry compressed air.

  • Working pressure: It needs to match the pressure of the air compressor (normal low pressure 0.7-1.0 MPa, medium high pressure requires custom special models).
  • Environment and inlet air temperature: For every 5°C increase in temperature, the moisture content in the air and the cooling load will increase significantly. Excessive high environmental temperatures in summer can easily cause the dehumidifier to shut down or result in poor water removal effect.
baiduimg.webp

 

Flow rate (m³/min): During the selection process, the processing capacity of the dehumidifier must be greater than the actual exhaust volume of the air compressor. It is generally recommended to increase it by 1.2 to 1.5 times to cope with extreme conditions such as high temperatures and high humidity in summer..

baiduimg.webp

 

Pressure dew point (PDP): The standard pressure dew point of the dehumidifier is usually between 2 and 10°C, corresponding to the atmospheric pressure dew point of approximately -17°C to -23°C. If the process requires a lower dew point (such as -40°C or -70°C), an adsorption dryer (desiccant dryer) should be used in conjunction.

     1. By cooling method

  • Air-cooled type: Utilizes fan for heat dissipation, easy to install, suitable for small to medium air volume or situations where water source is limited and environmental temperature is low.
  • Water-cooled type: Utilizes cooling water for heat dissipation, with stable cooling effect, suitable for systems with large air volume, high environmental temperature or dusty conditions.
    2. By intake temperature
  • Normal temperature type: The intake temperature is generally ≤ 45°C, suitable for systems with a high-efficiency rear cooler at the front end.
  • High temperature type: The intake temperature can reach below 80°C, suitable for systems where the exhaust temperature of the air compressor is high and there is no independent cooler.
 
49c9f894-8110-4292-8d2f-efe1d6974006

The four advantages of this integrated design

  • Plug-and-play, no installation required: Eliminates the hassle of connecting complex pipelines on-site in traditional post-processing systems, saving time and effort.
  • Space-saving: The vertical and compact layout minimizes the floor space, making it ideal for factories or workstations with limited space.
  • Low pressure loss: The pipelines have been professionally optimized, with short bends and connection distances, minimizing the pressure drop (pressure loss) of compressed air during the post-processing process.
  • Better compatibility: The cold dryer, tank, and filter are pre-matched for flow and pressure at the factory, avoiding "overpowered vehicles pulling small carts" or incomplete water removal issues caused by improper user selection.

.

Disassembly of the core structure of the equipment

     1. The deep blue square cabinet on the left: Refrigerated  dryer (cold dryer)

  • As the first-level water removal core, it is used to cool the compressed air and condense and separate most of the gaseous water and oil mist.

    2. The tall blue vertical tank on the right: Air storage tank / Deep adsorption or filtration unit
  • This tank plays a role in stabilizing the pressure of the pipeline network, buffering the airflow, and further sedimenting moisture in the integrated system. Depending on the design of some laser-cut or high-precision industry integrated machines, some internal parts may also incorporate precision filter cores.

    3. Bottom and connecting pipelines:
  • The entire assembly uses an integrated skid base. The pipelines are already welded and connected at the factory, equipped with a drain valve and pressure gauge. Users can simply connect the main air inlet and outlet on site to put it into use.
3ddf6bbc-0fa9-437b-8cd6-a6a7f8f05dda

 

b4e3c4bb-f648-42ef-b07f-27441645b9b5b25fde3b-9e7d-4b18-96ae-4bde64a4fcad

Hot Tags: refrigerated compressed air dryer, China refrigerated compressed air dryer manufacturers, suppliers, factory, acre homestead freeze dryer, countertop freeze dryer, freeze dryer laboratory price, freeze dryer lyophilizer price, freezedryers, micro freeze dryer

Technical Parameters

 

 

Model Treatment air
volume
Air inlet and outlet pipe diameter Overall
dimension
mm
Weight
KG
TKW-1 1.6 G1 850 565 1470 180
TKW-2 2.6 DN25 910 565 1510 220
TKW-3 3.8 DN40 1170 565 1585 310
TKW-6 6.5 DN40 1170 565 2005 385
TKW-8 8.5 DN40 1220 565 1850 420
TKW-10 11.5 DN50 1370 620 2405 670
TKW-12 13.5 DN50 1370 620 2405 720
TKW-15 17 DN65 1650 710 2460 990
TKW-20 20 DN65 1850 910 2480 1020
TKW-25 25 DN65 1850 810 2530 1060
TKW-30 32 DN80 1820 790 2575 1430
TKW-35 38 DN100 2890 810 2780 1470
TKW-40 45 DN100 2890 810 2780 1610
TKW-50 55 DN100 2130 960 2770 1780
TKW-60 65 DN125 2410 980 3030 2020
TKW-70 75 DN125 2460 1025 3050 2420
TKW-90 90 DN125 2640 1130 3245 2640
TKW-110 110 DN150 2710 1230 3300 3335
TKW-130 130 DN150 2810 1340 3350 3670
TKW-160 160 DN150 2810 1340 3350 4265
TKW-210 210 DN200 3810 2000 3350 6400
TKW-260 260 DN200 4000 2500 3350 7560
TKW-310 310 DN250 5500 2800 3350 10000
Send Inquiry